$0.00
Huawei H19-311 Dumps

Huawei H19-311 Exam Dumps

Huawei Certified Pre-sales Associate- Data Center Facility

Total Questions : 225
Update Date : November 01, 2024
PDF + Test Engine
$65 $95
Test Engine
$55 $85
PDF Only
$45 $75



Last Week H19-311 Exam Results

64

Customers Passed Huawei H19-311 Exam

99%

Average Score In Real H19-311 Exam

97%

Questions came from our H19-311 dumps.



Choosing the Right Path for Your H19-311 Exam Preparation

Welcome to PassExamHub's comprehensive study guide for the Huawei Certified Pre-sales Associate- Data Center Facility exam. Our H19-311 dumps is designed to equip you with the knowledge and resources you need to confidently prepare for and succeed in the H19-311 certification exam.

What Our Huawei H19-311 Study Material Offers

PassExamHub's H19-311 dumps PDF is carefully crafted to provide you with a comprehensive and effective learning experience. Our study material includes:

In-depth Content: Our study guide covers all the key concepts, topics, and skills you need to master for the H19-311 exam. Each topic is explained in a clear and concise manner, making it easy to understand even the most complex concepts.
Online Test Engine: Test your knowledge and build your confidence with a wide range of practice questions that simulate the actual exam format. Our test engine cover every exam objective and provide detailed explanations for both correct and incorrect answers.
Exam Strategies: Get valuable insights into exam-taking strategies, time management, and how to approach different types of questions.
Real-world Scenarios: Gain practical insights into applying your knowledge in real-world scenarios, ensuring you're well-prepared to tackle challenges in your professional career.

Why Choose PassExamHub?

Expertise: Our H19-311 exam questions answers are developed by experienced Huawei certified professionals who have a deep understanding of the exam objectives and industry best practices.
Comprehensive Coverage: We leave no stone unturned in covering every topic and skill that could appear on the H19-311 exam, ensuring you're fully prepared.
Engaging Learning: Our content is presented in a user-friendly and engaging format, making your study sessions enjoyable and effective.
Proven Success: Countless students have used our study materials to achieve their H19-311 certifications and advance their careers.
Start Your Journey Today!

Embark on your journey to Huawei Certified Pre-sales Associate- Data Center Facility success with PassExamHub. Our study material is your trusted companion in preparing for the H19-311 exam and unlocking exciting career opportunities.

Huawei H19-311 Sample Question Answers

Question # 1

Which of the following is not the certifications obtained by the UPS2000-G series? ()

A. Enhanced Capital Allowance (ECA) tax allowance
B. Energy Star certification
C. Green Sites award
D. CE certification



Question # 2

For two UPS5000-E (50 kA power module) 150 kVA with 2+0 rack redundancy, a () general input switch is required for the general input power distribution cabinet.

A. 250 A
B. 320 A
C. 500 A
D. 630 A



Question # 3

The FusionModule500 license is free for up to 50 sites, but is charged for more than 50 sites. 

A. TRUE
B. FALSE



Question # 4

The UPS5000-A features wide voltage and frequency input range. It can be used in severe grid environments and extend the battery service life. What's the maximum input voltage range of the UPS5000-A?

A. 138-85 V
B. 305-85 V
C. 240-80 V



Question # 5

The UPS5000-E (25-75 kVA) can be wall-mounted.

A. TRUE
B. FALSE



Question # 6

As the construction cost of the equipment room is high, reducing the floor area can efficiently save investment for clients. The floor area of a UPS5000-A-500K is ().

A. 1.02 m2
B. 2m2
C. 0.51 m2



Question # 7

The efficiency of the UPS5000-E (25-75 kVA) power module is 96%.

A. TRUE
B. FALSE



Question # 8

Which of the following elements will affect the application of HVDC in the equipment room? (Multiple Choice)

A. The standard is not complete, and multiple 240 V/336 V systems exist.
B. Not all loads can use the DC power supply directly,
C. The cost of DC circuit breaker components is high.
D. The efficiency is low.



Question # 9

Which of the following is the maintenance bypass implementation mode of the UPS2000-G series (6 kVA to 20 kVA)? ()

A. The UPS2000-G provides a built-in maintenance bypass.
B. A PDU is configured to support a maintenance bypass.
C. Maintenance bypass is unsupported.



Question # 10

The bypass module of the UPS5000-E-200K (50 kVA power module) is the same as that of the UPS5000-E-300K.

A. TRUE
B. FALSE



Question # 11

How many batteries does the UPS2000-G series (15 kVA to 20 kVA) support? () (Multiple Choice) 

A. 28
B. 32
C. 36
D. 40



Question # 12

Which of the following statements are correct about the UPS5OO0-A-400/500K usability? (Multiple Choice)

A. The parallel board is configured.
B. The UPS floor area is only 1.02 m2.
C. The number of batteries is adjustable.
D. Smart battery management is supported.



Question # 13

Which of the following elements shall be considered when configuring a UPS? (Multiple Choice)

A. UPS model, capacity, and parallel system mode
B. Battery brand and capacity
C. Brand and model of the AC and DC cables
D. Configuration of the battery rack and battery switch box



Question # 14

If the total current of a battery string is 1000 A and three battery strings are configured, the most economic cable configuration between the UPS and the main switch box is (): 

A. 120 mm2 (382 A) x 3
B. 150 mm2 (441 A) x 3
C. 185 mm2 (506 A) x 3
D. 240 mm2 (599 A) x 3



Question # 15

The output capacity of a single UPS is calculated on actual power when the actual load power is used for UPS configuration.

A. TRUE
B. FALSE



Question # 16

Conformal coating can effectively reduce the failure rate of the UPS in severe conditions/ including salt mist, dust, and high temperature and humidity, which ensures its service life in severe conditions.

A. TRUE
B. FALSE



Question # 17

The operating temperature range of the FusionModule800 is -20°C to +45°C, and that for the Fusion Mod ule500 is 0°C to 40°C.

A. TRUE
B. FALSE



Question # 18

Which of the following is not a configuration option of the 20-kVA UPS2000-G? ()

A. 4+0
B. 3+1
C. Dual-bus system
D. Battery string sharing



Question # 19

Which of the following UPS models support bypass hot-swap? (Multiple Choice)

A. UPS5000-E
B. UPS5000-A
C. APM series
D. PX250 series



Question # 20

According which of the following statements can you determine that the battery is faulty? (Multiple Choice)

A. The voltage increase of a battery is faster than the other batteries.
B. The temperature of the battery string during discharge is 2°C higher than the surrounding ambient temperature.
C. A battery suffers from obvious bulge and leakage.
D. The voltage drop of a battery is obviously faster than the other batteries.



Question # 21

The bypass module in the UPS5000-E-200K is the same as that in the UPS5000-E-400K.

A. TRUE
B. FALSE



Question # 22

Which of the following are the optional components for the UPS2000-G series (6 kVA to 20 kVA)? () (Multiple Choice) 

A. Temperature and humidity sensor
B. Battery temperature sensor
C. Transformer
D. PDU



Question # 23

The Fusion Mod ule500 adopts free cooling.

A. TRUE
B. FALSE